MAIN CONTACT
Max voltage: 250VAC
Resistive load max: 16 A
Motor load max: 4 A
FLOOD PROTECTION CONTACT
Max voltage: 250 VAC
Resistive load max: 1 A
Motor load max: 1 A


The terminal housing is made from plastic resistant toGLOW-WIRE TEST at 850°C.
The type 760 pressure switch consists of a moving diaphragm and disc which activate a changeover contact (snap action).
The contact can be calibrated to trip and reset at the desired pressure levels.
The main contact may also close a secondary creep action contact in series when it travels beyond the trip position (floodprotectioncontact ).
The main contact may also have a safety "heating element protector" which allows resettingevenif thecontacts havewelded onthetripside.
The main application is to control the level ofwater inappliances.
May also provide flood protection and heater protection.
Available with lateral spout, angular position as specified by customer ( ), or withCENTRALspout.
On the lateral spout version, the cap can haveanintegral clipfor snap-inmounting.
The mounting position must be indicated on the customer's drawing as it has an influenceoncalibration.
© Copyright 2004 by AFTERCODE.com - All rights reserved
download
Brochure Pressure